TED1001/2 cheap pointer temperature regulator thermostat

FOB Reference Price:Get Latest Price
$3.90 - $7.80 / Pieces | 10 Piece/Pieces (Min. Order)
Usage:
Industrial
Theory:
Temperature Controller
Accuracy:
0.5%F.S; 1.0%F.S
Temperature range:
0-400C
Report Suspicious Activity
Overview
Quick Details
Place of Origin:
Zhejiang, China
Brand Name:
CJ
Model Number:
TED1001/2
Color::
beige
Packaging::
Standard Export package
Operational Power Supply::
90VAC~242VAC,50HZ/60HZ
Accuracy::
class 1.0%F.S
Input signal::
thermocople or termresistance
control method::
on/off; time proportional-on/off
External dimensions::
72x72x130mm
installation hole::
68x68mm
Normal working circumstance::
temperature 0~50c
Approx::
400g
Supply Ability
Supply Ability:
50000 Piece/Pieces per Month
Packaging & Delivery
Packaging Details
1pcs/box for TED1001/2 cheap pointer temperature regulator thermostat
Port
all chiese port can send TED1001/2 cheap pointer temperature regulator thermostat

 

 

 

 

          TED1001/2 cheap pointer temperature regulator thermostat applies special technique to resist interference and adopts time proportion control method. It can be used as temperature measurement and control automatically under all kinds of light and heavy industry department as metallurgy,chemical,electronic,machinery,textile,plastic,refrigeration,medical treatment,electric oven and so on.

 

Technical specification:

  1. Input type: K
  2. Range: 0~400℃
  3. Accuracy of display: ≤ 2.5%FS
  4. Accuracy of control: ≤ 1.5%FS
  5. Contact capacity: 220VAC, 7A(resistance load)
  6. Power supply: AC110~242V , 50/60Hz
  7. Power consumption :< 3W  
  8. Overall size and installation hole: 72×72×120mm ;  68×68mm
  9. Working environment: temperature: 0~50℃; relativehumidity: < 85% RH,without corrode gas .

 

 Connection Scheme(consult)

 

 

 

  

 

 Use and adjustment

 

 

 

 

 

 

Method to use:

 

 

          Connect the power and the sensor according to the connection Scheme,then it displays the actual measure temperature.

 

The terminals of ‘1’, ‘2’ are input of thermocouple signal, the terminals of ‘7’, ‘8’, ‘9’ are relay control output. The terminal of ‘11’, ‘12’ are power supply (AC110~242V).

 

When the actual measure temperature haven’t entered the proportional band and the setting temperature is higher than the actual measure temperature, the relay is connected at terminal “8” and “9” and is disconnected at terminal “8” and “7” . The load starts heating at this time and its temperature is going up.

 

When the actual measure temperature haven’t entered the proportional band and the setting temperature is lower than the actual measure temperature, the relay is disconnected at terminal “8” and “9” and is connected at terminal “8” and “7” . The load does not heat at this time and its temperature is going down.

 

After the actual measure temperature entry into the proportional band, the relay start opening and closing according to the controlling rule . The higher temperature and the shorter connecting time of relay between terminal “8” and “9 ”. vice versa .The controller control the temperature by the way of changing the average heating power of load.

 

 

 

The maintenance and attention of controller.

  1. The controller should be installed in the condition without corrode gas.
  2. Thermocouple should be put in the place where it can measure real temperature inside the furnace and has good insulation with heating element of furnace .
  3. Before powering on the controller, please check it carefully to see if all connection is correct and if thermocouple can match with input type of controller .
  4. When heating initially, although the power of heating element inside furnace has been turned off, the temperature of furnace will keep going up because of the heating inertia inside furnace. So it is better to set about 80% of temperature you want to set normally before powering on the controller every time. After controller carry out “on-off control “for several times, then set temperature you want to set normally , so as to avoid over surging.
  5. If the controller displays abnormally, check the sensor to see if its connection is open circuit or short circuit, also check if the working voltage of controller is normal.